A voltmeter, an ammeter and a wattmeter connected to a single-phase inductive load read 240 V, 16 A and 3648 W. Find the power factor cos φ of the load.
AC power & power factor worksheet with answers
A load takes 26 kW of real power and 6.5 kvar of reactive power (lagging). Find the apparent power S.
A single-phase motor takes 29 kW at a power factor of 0.75 lagging from a 400 V supply. Find the reactive power Q it draws.
A load with impedance Z = 7 + j24 Ω is connected to a 240 V (rms) single-phase supply. Find the reactive power Q it absorbs.
A single-phase load takes 25 kW at a power factor of 0.7 lagging from a 400 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the reactive power QC the capacitor must supply.
A single-phase load takes 2 kW at a power factor of 0.7 lagging from a 230 V, 50 Hz supply. A 68 µF capacitor is connected in parallel with the load. Find the new line current I.
Answer key
- 1. cos φ = 0.95
- 2. S = 26.8 kVA
- 3. Q = 25.58 kvar
- 4. Q = 2212 var
- 5. QC = 14.86 kvar
- 6. I = 9.554 A
Full step-by-step solutions: practise this topic on examproblems.com.