AC power & power factor worksheet with answers

Free printable AC power & power factor worksheet: 6 problems from easy to exam level, with an answer key. Print it or save it as a PDF.

For teachers: free to print, copy and use in class. Every new worksheet has new values and its own answer key. A link to ExamProblems on your course page is appreciated.

Name: ____________________   Date: ____________

1.Easy
240 VloadP = 3648 W16 A

A voltmeter, an ammeter and a wattmeter connected to a single-phase inductive load read 240 V, 16 A and 3648 W. Find the power factor cos φ of the load.

V = 240 VI = 16 AP = 3648 W
cos φ =
2.Easy
P = 26 kWQ = 6.5 kvarS = ?φ

A load takes 26 kW of real power and 6.5 kvar of reactive power (lagging). Find the apparent power S.

P = 26 kWQ = 6.5 kvar
S = kVA
3.Medium
P = 29 kWQ = ?Sφ

A single-phase motor takes 29 kW at a power factor of 0.75 lagging from a 400 V supply. Find the reactive power Q it draws.

P = 29 kWpf = 0.75V = 400 V
Q = kvar
4.Medium
240 VZ7 + j24 ΩI

A load with impedance Z = 7 + j24 Ω is connected to a 240 V (rms) single-phase supply. Find the reactive power Q it absorbs.

V = 240 VZ = 7 + j24 Ω
Q = var
5.Hard
P = 25 kWQ1​S1​φ1​QC​

A single-phase load takes 25 kW at a power factor of 0.7 lagging from a 400 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the reactive power QC the capacitor must supply.

P = 25 kWpf1 = 0.7pf2 = 0.92V = 400 Vf = 50 Hz
QC = kvar
6.Hard
230 V50 Hzload2 kW, 0.7C68 µFI = ?

A single-phase load takes 2 kW at a power factor of 0.7 lagging from a 230 V, 50 Hz supply. A 68 µF capacitor is connected in parallel with the load. Find the new line current I.

P = 2 kWpf1 = 0.7V = 230 Vf = 50 HzC = 68 µF
I = A

Answer key

  1. 1. cos φ = 0.95
  2. 2. S = 26.8 kVA
  3. 3. Q = 25.58 kvar
  4. 4. Q = 2212 var
  5. 5. QC = 14.86 kvar
  6. 6. I = 9.554 A

Full step-by-step solutions: practise this topic on examproblems.com.