A single-phase load draws 17 A (rms) from a 120 V (rms) supply at a power factor of 0.65 lagging. Find the real power P it takes.
AC power & power factor worksheet with answers
A single-phase load draws 20 A (rms) from a 240 V (rms) supply at a power factor of 0.95 lagging. Find the reactive power Q it takes.
An inductive load takes 2 A and 432 W from a 240 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.
A single-phase motor takes 33 kW at a power factor of 0.6 lagging from a 240 V supply. Find the line current I.
A 10 V (rms), 1000 Hz source has an internal impedance Zs = 8 + j20 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.
A single-phase load takes 7 kW at a power factor of 0.7 lagging from a 240 V, 50 Hz supply. A 220 µF capacitor is connected in parallel with the load. Find the new line current I.
Answer key
- 1. P = 1326 W
- 2. Q = 1499 var
- 3. X = 52.31 Ω
- 4. I = 229.2 A
- 5. Pmax = 3.125 W
- 6. I = 32 A
Full step-by-step solutions: practise this topic on examproblems.com.