A single-phase load draws 17 A (rms) from a 120 V (rms) supply at a power factor of 0.85 lagging. Find the reactive power Q it takes.
AC power & power factor worksheet with answers
A load takes 22 kW of real power and 6.5 kvar of reactive power (lagging). Find the apparent power S.
A load with impedance Z = 5 + j12 Ω is connected to a 120 V (rms) single-phase supply. Find the reactive power Q it absorbs.
A single-phase motor takes 5 kW at a power factor of 0.7 lagging from a 400 V supply. Find the reactive power Q it draws.
A single-phase load takes 5 kW at a power factor of 0.7 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.98. Find the reactive power QC the capacitor must supply.
A single-phase load takes 20 kW at a power factor of 0.6 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the reactive power QC the capacitor must supply.
Answer key
- 1. Q = 1075 var
- 2. S = 22.94 kVA
- 3. Q = 1022 var
- 4. Q = 5.101 kvar
- 5. QC = 4.086 kvar
- 6. QC = 18.15 kvar