An ideal boost converter must produce 60 V from 24 V in continuous conduction. Find the duty cycle D.
DC-DC converters worksheet with answers
An ideal inverting buck-boost converter must produce −12 V from 36 V in continuous conduction. Find the duty cycle D.
An ideal boost converter turns 12 V into 20 V for a 2 Ω load. Find the average inductor current IL.
An ideal buck converter turns 15 V into 6 V at a switching frequency of 25 kHz. Find the inductance L that keeps the peak-to-peak inductor ripple current at 0.4 A.
An ideal inverting buck-boost converter turns 36 V into −84 V for a 25 Ω load at 40 kHz. Find the smallest inductance Lcrit for continuous conduction.
An ideal boost converter turns 24 V into 60 V for a 2 Ω load at 250 kHz. The output capacitor is 47 µF. Find the peak-to-peak output voltage ripple ΔVo in mV.
Answer key
- 1. D = 0.6
- 2. D = 0.25
- 3. IL = 16.67 A
- 4. L = 360 µH
- 5. Lcrit = 28.13 µH
- 6. ΔVo = 1532 mV