Hot oil (2 kg/s, cp = 2.5 kJ/(kg·K)) cools from 175 to 115 °C in a counter-flow exchanger. It heats 1 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. No heat is lost to the surroundings. Find the water outlet temperature Tc,out.
Heat exchangers (LMTD) worksheet with answers
Hot oil (0.5 kg/s, cp = 2.5 kJ/(kg·K)) cools from 165 to 95 °C in a counter-flow exchanger. It heats 1 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. No heat is lost to the surroundings. Find the water outlet temperature Tc,out.
A parallel-flow heat exchanger transfers 110 kW. The hot fluid cools from 130 to 115 °C and the cold fluid heats from 30 to 100 °C. The overall heat transfer coefficient is 1000 W/(m²·K). Find the heat transfer area A needed.
A shell-and-tube heat exchanger (one shell pass, two tube passes) must transfer 350 kW. The hot fluid cools from 165 to 145 °C and the cold fluid heats from 20 to 120 °C. The LMTD correction factor for this arrangement is F = 0.9, and U = 300 W/(m²·K). Find the heat transfer area A needed.
Steam condenses at a constant 110 °C on the outside of the tubes of a condenser with a heat transfer area of 6 m² and U = 2500 W/(m²·K). Cooling water (3 kg/s, cp = 4.18 kJ/(kg·K)) enters the tubes at 20 °C. Find the water outlet temperature Tc,out.
Hot oil (1.5 kg/s, cp = 2.5 kJ/(kg·K)) cools from 110 to 60 °C in a counter-flow exchanger. It heats 1 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 15 °C. With U = 500 W/(m²·K), find the heat transfer area A needed.
Answer key
- 1. Tc,out = 101.8 °C
- 2. Tc,out = 50.93 °C
- 3. A = 2.455 m²
- 4. A = 16.55 m²
- 5. Tc,out = 82.79 °C
- 6. A = 7.891 m²
Full step-by-step solutions: practise this topic on examproblems.com.