A proportional controller K = 3 drives the plant G(s) = 2/(s + 1) in a unity-feedback loop. A step of size 10 is applied. Find the final value of the output y(∞).
Steady-state error & PID control worksheet with answers
A proportional controller K = 2 drives the plant G(s) = 5/(s + 10) in a unity-feedback loop. A step of size 10 is applied. Find the final value of the output y(∞).
The parabolic input r(t) = 2·t²/2 is applied to a unity-feedback loop with G(s) = 4(s + 2)/(s²(s + 10)). Find the steady-state error ess.
A unity-feedback loop has G(s) = K/((s + 2)(s + 4)). Find the gain K that gives a steady-state error of 25 % for a step input.
A proportional controller K = 2 drives the plant G(s) = 5/(s(s + 2)) in a unity-feedback loop. Find the peak time tp of the step response.
A proportional controller K = 20 drives the plant G(s) = 10/(s(s + 4)) in a unity-feedback loop. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
Answer key
- 1. y(∞) = 8.571
- 2. y(∞) = 5
- 3. ess = 2.5
- 4. K = 24
- 5. tp = 1.047 s
- 6. ts = 2 s
Full step-by-step solutions: practise this topic on examproblems.com.