ECG Interpretation: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

ECG rhythm strip interpretation

Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)

Method

  1. Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
  2. Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
  3. P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
  4. PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
  5. QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.

2Practice problems

1.ECG rhythm strip interpretationMedium
II25 mm/s · 10 mm/mVfirst-degree AV blockatrial fibrillationjunctional rhythmnormal sinus rhythm

Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
  1. 1first-degree AV block
  2. 2atrial fibrillation
  3. 3junctional rhythm
  4. 4normal sinus rhythm
2.ECG rhythm strip interpretationHard
II25 mm/s · 10 mm/mVsinus rhythm with wide QRSidioventricular rhythmdual-chamber (AV) paced rhythmpaced rhythm, failure to capture

This patient has a pacemaker. Interpret the lead II strip. Click your answer.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
  1. 1sinus rhythm with wide QRS
  2. 2idioventricular rhythm
  3. 3dual-chamber (AV) paced rhythm
  4. 4paced rhythm, failure to capture
3.Human physiologyMedium

Mean arterial pressure is approximately equal to:

  1. ACardiac output × total peripheral resistance
  2. BStroke volume × total peripheral vascular resistance
  3. CHeart rate × stroke volume
  4. DCardiac output ÷ heart rate
4.Human physiologyHard

A healthy person stands up quickly after lying down. Which reflex response prevents fainting?

  1. AThe chemoreceptor reflex raises breathing rate and arterial oxygen levels
  2. BADH release immediately doubles blood volume
  3. CThe baroreceptor reflex raises heart rate and vasoconstriction
  4. DThe Bainbridge reflex lowers heart rate

3Solutions

1.ECG rhythm strip interpretation

Answer: junctional rhythm

Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.

Five steps

1. Rate: R–R = 28 small boxes, 1500 ÷ 28 ≈ 54 per minute.
2. Rhythm: regular, every R–R is 1.12 s.
3. P waves: none visible.
4. PR interval: not measurable.
5. QRS: 0.08 s, narrow (below 0.12 s).

Interpretation

junctional rhythm

Answer

junctional rhythm
2.ECG rhythm strip interpretation

Answer: dual-chamber (AV) paced rhythm

Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.

Five steps

1. Rate: R–R = 25 small boxes, 1500 ÷ 25 ≈ 60 per minute.
2. Rhythm: regular, every R–R is 1.00 s.
3. P waves: each P wave follows its own pacing spike (atrial pacing).
4. AV interval: the second spike comes 0.20 s after the first one (the programmed AV delay).
5. QRS: 0.16 s, wide, right after the second spike (ventricular pacing).

Interpretation

dual-chamber (AV) paced rhythm

Answer

dual-chamber (AV) paced rhythm

The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.

3.Human physiology

Answer: A · Cardiac output × total peripheral resistance

Why this is the answer

Pressure = flow × resistance, so MAP ≈ CO × TPR. Changes in either cardiac output or vascular resistance change blood pressure.

Answer

A · Cardiac output × total peripheral resistance
4.Human physiology

Answer: C · The baroreceptor reflex raises heart rate and vasoconstriction

Why this is the answer

Blood pools in the legs and pressure falls; baroreceptors fire less, which increases sympathetic and decreases vagal activity within seconds, raising heart rate and vascular tone.

Answer

C · The baroreceptor reflex raises heart rate and vasoconstriction

ExamProblems · examproblems.com/courses/ecg-interpretation