In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Measure the QT interval on this lead II strip, in seconds.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
QT = s
2.ECG rhythm strip interpretationHard
Identify the rhythm on this lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1ventricular fibrillation
2ventricular tachycardia
3atrial fibrillation
4torsades de pointes
3.Human physiologyMedium
According to Poiseuille's law, if the radius of an arteriole halves, its resistance to flow:
ADoubles
BHalves
CIncreases 4-fold
DIncreases about 16-fold
4.Human physiologyHard
A patient hyperventilating during a panic attack has tingling fingers. What would the arterial blood gas most likely show?
AHigh pH and low PaCO₂
BLow pH and low bicarbonate
CLow pH and high PaCO₂
DHigh pH and high bicarbonate
3Solutions
1.ECG rhythm strip interpretation
Answer: QT = 0.32 s
QT and QTc: the QT interval runs from the start of the QRS complex to the end of the T wave. It shortens as the heart rate rises, so it is corrected for rate with the R–R interval in seconds: Bazett QTc = QT/√RR and Fridericia QTc = QT/∛RR. Bazett is the formula most textbooks use; it over-corrects at fast rates, where Fridericia is preferred. Limits differ between references: a QTc above about 0.45 s in men or 0.46 s in women is usually called prolonged, and above 0.50 s markedly prolonged.
Measure
8 small boxes from the start of the QRS to the end of the T wave
Convert
QT = 8 × 0.04 s = 0.32 s
Answer
QT = 0.32 s
A rough rule: at normal rates the QT should be less than half the R–R interval (here R–R = 0.60 s).
2.ECG rhythm strip interpretation
Answer: ventricular fibrillation
Ventricular rhythms: ventricular tachycardia is a run of three or more wide (0.12 s or more) complexes in a row at more than 100/min, usually 150–250/min, regular, without related P waves. Ventricular fibrillation is a chaotic, irregular waveform with no identifiable P waves, QRS complexes or T waves and no countable rate. Asystole is an almost flat line with no ventricular activity; a flat line is always confirmed by checking the patient, the leads and the gain and a second lead. In resuscitation guidelines VF and pulseless VT are the shockable rhythms and asystole is not.
Five steps
1. Rate: no countable ventricular rate.
2. Rhythm: chaotic, no repeating pattern.
3. P waves: none identifiable.
4. PR interval: not measurable.
5. QRS: no QRS complexes.
Interpretation
ventricular fibrillation
Answer
ventricular fibrillation
In resuscitation guidelines VF and pulseless VT are the shockable rhythms. This is identification practice only.
3.Human physiology
Answer: D · Increases about 16-fold
Why this is the answer
Resistance is proportional to 1/r⁴, so halving the radius raises resistance by 2⁴ = 16. This is why small changes in arteriole diameter control blood flow so strongly.
Answer
D · Increases about 16-fold
4.Human physiology
Answer: A · High pH and low PaCO₂
Why this is the answer
Hyperventilation blows off CO₂ and causes acute respiratory alkalosis. Alkalosis increases calcium binding to albumin, lowering ionised calcium and causing tingling.