1 公式与方法热传导
傅里叶定律 Q̇ = kAΔT/L
导热热阻 R = L/(kA)
对流热阻 R = 1/(hA)
串联热阻 Q̇ = ΔTtotal /ΣR
U 值 U = 1/(ΣR·A)
换热器 (LMTD)
热负荷 Q = U·A·ΔTlm
对数平均温差 ΔTlm = (ΔT1 − ΔT2 )/ln(ΔT1 /ΔT2 )
物流热量衡算 Q = ṁcp (Tin − Tout )
2 练习题1. 热传导 中等
混凝土, k = 1.4 100 mm 砖, k = 0.72 25 mm 24 °C 3 °C Q̇ = ? 一面墙由 100 mm 的混凝土和 25 mm 的砖组成,面积为 4 m²。外表面温度为 24 °C 和 3 °C。 求通过墙体的热流量 Q̇ 。
L1 = 100 mm, k1 = 1.4 W/(m·K) L2 = 25 mm, k2 = 0.72 W/(m·K) A = 4 m² T1 = 24 °C T3 = 3 °C
Q̇ = W
2. 热传导 困难
玻璃, k = 0.96 250 mm 发泡聚苯乙烯, k = 0.035 50 mm 室内 22 °C 室外 1 °C Ts = ? Q̇ 由 250 mm 玻璃和 50 mm 发泡聚苯乙烯组成的墙,将 22 °C 的房间与 1 °C 的室外空气隔开。对流换热系数室内为 6 W/(m²·K),室外为 25 W/(m²·K),墙面积为 12 m²。 求墙内表面的温度 Ts 。
L1 = 250 mm, k1 = 0.96 W/(m·K) L2 = 50 mm, k2 = 0.035 W/(m·K) A = 12 m² hi = 6 W/(m²·K) ho = 25 W/(m²·K) Troom = 22 °C Tout = 1 °C
Ts = °C
3. 换热器 (LMTD) 中等
长度 T 120 °C 15 °C 50 °C ΔT₁ ΔT₂ 冷凝蒸汽 在冷凝器中,蒸汽在管外以恒定的 120 °C 冷凝。冷却水(5 kg/s,cp = 4.18 kJ/(kg·K))在管内流动,从 15 °C 加热到 50 °C。总传热系数为 2000 W/(m²·K)。求所需的传热面积 A 。
Ts = 120 °C ṁ = 5 kg/s cp = 4.18 kJ/(kg·K) Tc : 15 → 50 °C U = 2000 W/(m²·K)
A = m²
4. 换热器 (LMTD) 困难
长度 T 145 °C 100 °C 32.94 °C 15 °C ΔT₁ ΔT₂ 逆流 热油(2 kg/s,cp = 2.5 kJ/(kg·K))在逆流换热器中从 145 冷却到 100 °C。它加热 3 kg/s 的水(cp = 4.18 kJ/(kg·K)),水的入口温度为 15 °C。已知 U = 800 W/(m²·K),求所需传热面积 A 。
ṁh = 2 kg/s cp,h = 2.5 kJ/(kg·K) Th : 145 → 100 °C ṁc = 3 kg/s cp,c = 4.18 kJ/(kg·K) Tc,in = 15 °C U = 800 W/(m²·K)
A = m²
3 溶液1. 热传导
答案: Q̇ = 791.3 W
热阻: 通过串联各层的稳态热流类似于通过串联电阻的电流:Q̇ = ΔT/ΣR,导热层 R = L/(kA),对流表面 R = 1/(hA)。各层的温降与其热阻成正比。
各层热阻 R1 = L1 /(k1 A) = (100/1000)/(1.4·4) = 0.01786 K/W
R2 = L2 /(k2 A) = (25/1000)/(0.72·4) = 0.008681 K/W
热流量 Q̇ = (T1 − T3 )/(R1 + R2 ) = 21/0.02654 = 791.3 W
2. 热传导
答案: Ts = 20.15 °C
热阻: 通过串联各层的稳态热流类似于通过串联电阻的电流:Q̇ = ΔT/ΣR,导热层 R = L/(kA),对流表面 R = 1/(hA)。各层的温降与其热阻成正比。
串联热阻 Ri = 1/(hi A) = 1/(6·12) = 0.01389 K/W
R1 = L1 /(k1 A) = (250/1000)/(0.96·12) = 0.0217 K/W
R2 = L2 /(k2 A) = (50/1000)/(0.035·12) = 0.119 K/W
Ro = 1/(ho A) = 1/(25·12) = 0.003333 K/W
ΣR = 0.158 K/W
热损失 Q̇ = (22 − (1))/0.158 = 132.9 W
Ts = Troom − Q̇·Ri = 22 − 132.9·0.01389 = 20.15 °C
3. 换热器 (LMTD)
答案: A = 4.237 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm , with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
由水侧求热负荷 Q̇ = 5·4.18·(50 − 15) = 731.5 kW
两端温差 ΔT₁ = 120 − 15 = 105 K
ΔT₂ = 120 − 50 = 70 K
对数平均温差 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (105 − 70)/ln(105/70) = 86.32 K
面积 A = Q̇/(U·ΔTlm ) = 731500/(2000·86.32) = 4.237 m²
4. 换热器 (LMTD)
答案: A = 2.873 m²
对数平均温差法 (LMTD): 两股流体之间的温差沿换热器变化,因此传热方程使用其对数平均值:Q̇ = U·A·ΔTlm ,其中 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂),ΔT₁ 和 ΔT₂ 为两端温差。进出口温度相同时,逆流的 ΔTlm 大于并流。
热负荷和水的出口温度 Q̇ = ṁh cp,h (Th,in − Th,out ) = 2·2.5·45 = 225 kW
Tc,out = 15 + 225/(3·4.18) = 32.94 °C
两端温差 逆流时,热流体入口对着冷流体出口,热流体出口对着冷流体入口。
ΔT₁ = Th,in − Tc,out = 145 − 32.94 = 112.1 K
ΔT₂ = Th,out − Tc,in = 100 − 15 = 85 K
对数平均温差 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (112.1 − 85)/ln(112.1/85) = 97.91 K
面积 A = Q̇/(U·ΔTlm ) = 225000/(800·97.91) = 2.873 m²