1 公式与方法热传导
傅里叶定律 Q̇ = kAΔT/L
导热热阻 R = L/(kA)
对流热阻 R = 1/(hA)
串联热阻 Q̇ = ΔTtotal /ΣR
U 值 U = 1/(ΣR·A)
换热器 (LMTD)
热负荷 Q = U·A·ΔTlm
对数平均温差 ΔTlm = (ΔT1 − ΔT2 )/ln(ΔT1 /ΔT2 )
物流热量衡算 Q = ṁcp (Tin − Tout )
2 练习题1. 热传导 中等
砖, k = 0.72 150 mm 混凝土, k = 1.4 50 mm 15 °C -1 °C Q̇ = ? 一面墙由 150 mm 的砖和 50 mm 的混凝土组成,面积为 15 m²。外表面温度为 15 °C 和 -1 °C。 求通过墙体的热流量 Q̇ 。
L1 = 150 mm, k1 = 0.72 W/(m·K) L2 = 50 mm, k2 = 1.4 W/(m·K) A = 15 m² T1 = 15 °C T3 = -1 °C
Q̇ = W
2. 热传导 困难
矿棉, k = 0.04 150 mm 木材, k = 0.17 25 mm 室内 20 °C 室外 2 °C Q̇ 由 150 mm 矿棉和 25 mm 木材组成的墙,将 20 °C 的房间与 2 °C 的室外空气隔开。对流换热系数室内为 10 W/(m²·K),室外为 20 W/(m²·K),墙面积为 4 m²。 求墙体的总传热系数 U 。
L1 = 150 mm, k1 = 0.04 W/(m·K) L2 = 25 mm, k2 = 0.17 W/(m·K) A = 4 m² hi = 10 W/(m²·K) ho = 20 W/(m²·K) Troom = 20 °C Tout = 2 °C
U = W/(m²·K)
3. 换热器 (LMTD) 中等
长度 T 170 °C 140 °C 20 °C 135 °C ΔT₁ ΔT₂ 并流 一台并流换热器传递 310 kW。 其传热面积为 6 m²。热流体从 170 °C 冷却到 140 °C,冷流体从 20 °C 加热到 135 °C。求总传热系数 U 。
Q̇ = 310 kW A = 6 m² Th : 170 → 140 °C Tc : 20 → 135 °C
U = W/(m²·K)
4. 换热器 (LMTD) 困难
长度 T 155 °C 50 °C 51.4 °C 20 °C ΔT₁ ΔT₂ 逆流 热油(1 kg/s,cp = 2.5 kJ/(kg·K))在逆流换热器中从 155 冷却到 50 °C。它加热 2 kg/s 的水(cp = 4.18 kJ/(kg·K)),水的入口温度为 20 °C。已知 U = 300 W/(m²·K),求所需传热面积 A 。
ṁh = 1 kg/s cp,h = 2.5 kJ/(kg·K) Th : 155 → 50 °C ṁc = 2 kg/s cp,c = 4.18 kJ/(kg·K) Tc,in = 20 °C U = 300 W/(m²·K)
A = m²
3 溶液1. 热传导
答案: Q̇ = 983.4 W
热阻: 通过串联各层的稳态热流类似于通过串联电阻的电流:Q̇ = ΔT/ΣR,导热层 R = L/(kA),对流表面 R = 1/(hA)。各层的温降与其热阻成正比。
各层热阻 R1 = L1 /(k1 A) = (150/1000)/(0.72·15) = 0.01389 K/W
R2 = L2 /(k2 A) = (50/1000)/(1.4·15) = 0.002381 K/W
热流量 Q̇ = (T1 − T3 )/(R1 + R2 ) = 16/0.01627 = 983.4 W
2. 热传导
答案: U = 0.2471 W/(m²·K)
热阻: 通过串联各层的稳态热流类似于通过串联电阻的电流:Q̇ = ΔT/ΣR,导热层 R = L/(kA),对流表面 R = 1/(hA)。各层的温降与其热阻成正比。
串联热阻 Ri = 1/(hi A) = 1/(10·4) = 0.025 K/W
R1 = L1 /(k1 A) = (150/1000)/(0.04·4) = 0.9375 K/W
R2 = L2 /(k2 A) = (25/1000)/(0.17·4) = 0.03676 K/W
Ro = 1/(ho A) = 1/(20·4) = 0.0125 K/W
ΣR = 1.012 K/W
总传热系数 U = 1/(A·ΣR) = 1/(4·1.012) = 0.2471 W/(m²·K)
3. 换热器 (LMTD)
答案: U = 1212 W/(m²·K)
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm , with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
两端温差 并流时,两个入口在同一端,两个出口在另一端。
ΔT₁ = Th,in − Tc,in = 170 − 20 = 150 K
ΔT₂ = Th,out − Tc,out = 140 − 135 = 5 K
对数平均温差 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (150 − 5)/ln(150/5) = 42.63 K
总传热系数 U = Q̇/(A·ΔTlm ) = 310000/(6·42.63) = 1212 W/(m²·K)
4. 换热器 (LMTD)
答案: A = 14.73 m²
对数平均温差法 (LMTD): 两股流体之间的温差沿换热器变化,因此传热方程使用其对数平均值:Q̇ = U·A·ΔTlm ,其中 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂),ΔT₁ 和 ΔT₂ 为两端温差。进出口温度相同时,逆流的 ΔTlm 大于并流。
热负荷和水的出口温度 Q̇ = ṁh cp,h (Th,in − Th,out ) = 1·2.5·105 = 262.5 kW
Tc,out = 20 + 262.5/(2·4.18) = 51.4 °C
两端温差 逆流时,热流体入口对着冷流体出口,热流体出口对着冷流体入口。
ΔT₁ = Th,in − Tc,out = 155 − 51.4 = 103.6 K
ΔT₂ = Th,out − Tc,in = 50 − 20 = 30 K
对数平均温差 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (103.6 − 30)/ln(103.6/30) = 59.39 K
面积 A = Q̇/(U·ΔTlm ) = 262500/(300·59.39) = 14.73 m²