1 公式与方法热传导
傅里叶定律 Q̇ = kAΔT/L
导热热阻 R = L/(kA)
对流热阻 R = 1/(hA)
串联热阻 Q̇ = ΔTtotal /ΣR
U 值 U = 1/(ΣR·A)
换热器 (LMTD)
热负荷 Q = U·A·ΔTlm
对数平均温差 ΔTlm = (ΔT1 − ΔT2 )/ln(ΔT1 /ΔT2 )
物流热量衡算 Q = ṁcp (Tin − Tout )
2 练习题1. 热传导 中等
发泡聚苯乙烯, k = 0.035 200 mm 木材, k = 0.17 50 mm 18 °C -7 °C Ti = ? Q̇ 一面墙由 200 mm 的发泡聚苯乙烯和 50 mm 的木材组成,面积为 6 m²。外表面温度为 18 °C 和 -7 °C。 求两层交界面处的温度 Ti 。
L1 = 200 mm, k1 = 0.035 W/(m·K) L2 = 50 mm, k2 = 0.17 W/(m·K) A = 6 m² T1 = 18 °C T3 = -7 °C
Ti = °C
2. 热传导 困难
玻璃, k = 0.96 150 mm 木材, k = 0.17 150 mm 室内 20 °C 室外 -8 °C Q̇ 由 150 mm 玻璃和 150 mm 木材组成的墙,将 20 °C 的房间与 -8 °C 的室外空气隔开。对流换热系数室内为 8 W/(m²·K),室外为 20 W/(m²·K),墙面积为 10 m²。 求墙体的总传热系数 U 。
L1 = 150 mm, k1 = 0.96 W/(m·K) L2 = 150 mm, k2 = 0.17 W/(m·K) A = 10 m² hi = 8 W/(m²·K) ho = 20 W/(m²·K) Troom = 20 °C Tout = -8 °C
U = W/(m²·K)
3. 换热器 (LMTD) 中等
长度 T 110 °C 75 °C 35 °C 25 °C ΔT₁ ΔT₂ 逆流 一台管壳式换热器(单壳程、双管程)须传递 100 kW。热流体从 110 °C 冷却到 75 °C,冷流体从 25 °C 加热到 35 °C。该布置的 LMTD 修正系数为 F = 0.8,U = 500 W/(m²·K)。求所需的传热面积 A 。
Q̇ = 100 kW F = 0.8 U = 500 W/(m²·K) Th : 110 → 75 °C Tc : 25 → 35 °C
A = m²
4. 换热器 (LMTD) 困难
长度 T 160 °C 90 °C 50.17 °C 15 °C ΔT₁ ΔT₂ 逆流 热油(1 kg/s,cp = 2.1 kJ/(kg·K))在逆流换热器中从 160 冷却到 90 °C。它加热 1 kg/s 的水(cp = 4.18 kJ/(kg·K)),水的入口温度为 15 °C。已知 U = 500 W/(m²·K),求所需传热面积 A 。
ṁh = 1 kg/s cp,h = 2.1 kJ/(kg·K) Th : 160 → 90 °C ṁc = 1 kg/s cp,c = 4.18 kJ/(kg·K) Tc,in = 15 °C U = 500 W/(m²·K)
A = m²
3 溶液1. 热传导
答案: Ti = −5.776 °C
热阻: 通过串联各层的稳态热流类似于通过串联电阻的电流:Q̇ = ΔT/ΣR,导热层 R = L/(kA),对流表面 R = 1/(hA)。各层的温降与其热阻成正比。
各层热阻 R1 = L1 /(k1 A) = (200/1000)/(0.035·6) = 0.9524 K/W
R2 = L2 /(k2 A) = (50/1000)/(0.17·6) = 0.04902 K/W
热流量 Q̇ = (T1 − T3 )/(R1 + R2 ) = 25/1.001 = 24.97 W
交界面温度 第一层中温度下降 Q̇·R₁。
Ti = T1 − Q̇·R1 = 18 − 24.97·0.9524 = −5.776 °C
2. 热传导
答案: U = 0.824 W/(m²·K)
热阻: 通过串联各层的稳态热流类似于通过串联电阻的电流:Q̇ = ΔT/ΣR,导热层 R = L/(kA),对流表面 R = 1/(hA)。各层的温降与其热阻成正比。
串联热阻 Ri = 1/(hi A) = 1/(8·10) = 0.0125 K/W
R1 = L1 /(k1 A) = (150/1000)/(0.96·10) = 0.01563 K/W
R2 = L2 /(k2 A) = (150/1000)/(0.17·10) = 0.08824 K/W
Ro = 1/(ho A) = 1/(20·10) = 0.005 K/W
ΣR = 0.1214 K/W
总传热系数 U = 1/(A·ΣR) = 1/(10·0.1214) = 0.824 W/(m²·K)
3. 换热器 (LMTD)
答案: A = 4.055 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm , with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
两端温差(逆流) 逆流时,热流体入口对着冷流体出口,热流体出口对着冷流体入口。
ΔT₁ = Th,in − Tc,out = 110 − 35 = 75 K
ΔT₂ = Th,out − Tc,in = 75 − 25 = 50 K
对数平均温差 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (75 − 50)/ln(75/50) = 61.66 K
面积 A = Q̇/(U·F·ΔTlm,cf ) = 100000/(500·0.8·61.66) = 4.055 m²
4. 换热器 (LMTD)
答案: A = 3.22 m²
对数平均温差法 (LMTD): 两股流体之间的温差沿换热器变化,因此传热方程使用其对数平均值:Q̇ = U·A·ΔTlm ,其中 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂),ΔT₁ 和 ΔT₂ 为两端温差。进出口温度相同时,逆流的 ΔTlm 大于并流。
热负荷和水的出口温度 Q̇ = ṁh cp,h (Th,in − Th,out ) = 1·2.1·70 = 147 kW
Tc,out = 15 + 147/(1·4.18) = 50.17 °C
两端温差 逆流时,热流体入口对着冷流体出口,热流体出口对着冷流体入口。
ΔT₁ = Th,in − Tc,out = 160 − 50.17 = 109.8 K
ΔT₂ = Th,out − Tc,in = 90 − 15 = 75 K
对数平均温差 ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (109.8 − 75)/ln(109.8/75) = 91.31 K
面积 A = Q̇/(U·ΔTlm ) = 147000/(500·91.31) = 3.22 m²